Private Healthcare
Imaging suites, sterilisation, medical gases and a building plant that cannot go down, on networks that grew with the hospital.

01What these plants run
What these plants run
A private hospital runs a plant: medical gas, sterilisation, the chiller and air handling that keep theatres at pressure, generators and uninterruptible power, and the building management system over all of it. Beside it runs a second plant, the clinical equipment: imaging modalities, laboratory analysers, infusion and monitoring devices, each a computer with a vendor behind it.
These devices are certified as supplied and serviced by their manufacturers, which is why the computer inside a scanner can run an operating system that is no longer supported. It is not negligence; it is how medical equipment is regulated.
What a passive capture hears first · HL7 / MLLP · 2575 · DICOM · 104, 11112 · Modbus TCP · 502

02Where the ways in usually are
A hospital’s imaging network is a plant network. Treat it that way.
The flat network is the pattern. Imaging workstations, the building plant and the office systems often share one network because the hospital grew faster than its network was redesigned. On that network, the oldest device sets the level of risk for all of them.
The other paths are the vendors: every modality and most of the building plant have a service contract with remote access, and the hospital rarely holds one list of them.
Patterns, not findings · client findings never appear on this site

We listen. We do not touch.
03 · Passive first
We treat the imaging network and the building plant as what they are, control networks, and we listen rather than scan, because an active scan against a scanner or an infusion pump is a patient-safety question before it is a security one.
The report lists the devices with their vendors and their paths, separates clinical, plant and office traffic, and sets out segmentation in stages the hospital can run between service windows. Compensating controls around equipment that cannot be patched get the same weight as patching would elsewhere.
Relevant standards
We work to published standards.
- ISA/IEC 62443Zones and conduits between clinical, plant and office networks.
- NIST SP 800-82Operational technology security guidance; the building plant is within its scope.
- Purdue / ISA-95The reference model for where an asset sits, from Level 0 to Level 5. See it as one scroll.