MFG · 09 / 09
Industries · 09 / 09 · Operational technology specialists, UAE
Manufacturing
Press lines, robot cells and conveyors run by PLCs that were commissioned once and have been added to ever since.

01What these plants run
What these plants run
A manufacturing floor runs on programmable logic controllers, one or several per line, talking to drives, robots, vision systems and safety relays over industrial Ethernet. Operators see the line through HMIs; supervisors see it through a SCADA or MES layer that collects counts, downtime and quality data.
The same floor usually carries a second generation of equipment alongside the first: a packing line from one integrator, a press from another, a robot cell with its own controller and its own network switch. Each arrived with its own drawings, and the drawings stopped matching the floor the first time a jumper was added to get a job out.
What a passive capture hears first · EtherNet/IP · 44818 · PROFINET · 34962–34964 · OPC UA · 4840

02Where the ways in usually are
The jumper that is not in any drawing is already in the drawing you don’t have.
The most common way in is a machine builder’s remote-support connection: a modem, a VPN appliance or a laptop-with-a-dongle left behind at commissioning so the vendor could help with teething problems. It did its job, the project closed, and it stayed.
The second is the network itself. Lines that were installed separately get bridged for an MES rollout or a dashboard, and the bridge is a plain switch rather than a firewall, so the office side and the machine side become one broadcast domain. A third is the engineering workstation that does programming for several lines and also reads email.
Patterns, not findings · client findings never appear on this site

We listen. We do not touch.
03 · Passive first
We start by listening. A passive capture at the right switch ports tells us what is on the floor, what it talks to and which conversations cross the boundary into the office, without sending a single packet into a controller.
The output is an asset list a plant manager can hold, ranked by what each path would allow, and a drawing of the floor as it is rather than as it was commissioned. Where a remote-support connection needs to stay, we describe how to keep it brokered, time-boxed and logged. Nothing is changed on the line until the plant has it in writing and a named person is beside us.
Relevant standards
We work to published standards.
- ISA/IEC 62443Zones, conduits and security levels for industrial automation; the primary reference.
- NIST SP 800-82Guide to operational technology security; useful for its network architecture section.
- Purdue / ISA-95The reference model for where an asset sits, from Level 0 to Level 5. See it as one scroll.
Related writing